The Issue
I had an issue on a recent project where I had a WGB-client directly connected to Gi0 on a Cisco IW3702 WGB that I wanted to be in VLAN200 so I configured the workgroup-bridge client-vlan 200
command, therefore the MAC address for this WGB-client should be in bridge-group 200 (BG200). However the WGB was being strange and putting the WGB-client into both the BG1 and BG200 bridging tables which would break communications as the WGB didn’t know where to correctly forward packets intended for this client!
I am running the latest recommended code (ap3g2-k9w7-tar.153-3.JPM) so I think it might be a bug, I also know that Cisco doesn’t recommended multiple VLAN deployments behind a WGB but it is possible and widely used in my experience.
It seems like the WGB doesn’t active the client-vlan config until after the interface fires up and that is how the MAC ends up in both bridging tables?
Work Around
I came up with a workaround by using a MAC ACL to block the WGB-client MAC from being able to communicate on BG1 as below. This works fine but I donβt think this is intended behaviour.
!
interface GigabitEthernet0
bridge-group 1 input-address-list 700
bridge-group 1 output-address-list 700
!
access-list 700 deny 000a.7529.f32e 0000.0000.0000
!
Until I figured out the above solution I was using a Python script to SSH into the WGB and clear the BG1 table.
|
|